CE Course 4 - References

References

  1. Evidence-Based Medicine Working Group: Evidence-based medicine: A new approach to teaching the practice of medicine. J Am Med Assoc 1992; 268(17):2420-2425.
  2. Oxman AD, Sackett DL, Guyatt GH: Users guides to the medical literature: How to get started. J Am Med Assoc 1993;270(17):2093-2095.
  3. Yukna RA, Shaklee RL: Evaluation of a counter-rotational powered brush in clients in supportive periodontal therapy. J Periodontol 1993;64:859-864.
  4. Tritten CB, Armitage GC: Comparison of a sonic and a manual toothbrush for efficacy in supragingival plaque removal and reduction of gingivitis. J Clin Periodontol 1996;23:641-648.
  5. Stolz K, Bay L: Comparison of a manual and new electric toothbrush for controlling plaque and gingivitis. J Clin Periodontol 1994;21:86-90.
  6. van der Weijen GA, Timmerman MF, Reijerse E: Danser MM, Mantel MS, Nijboer A, van der Velden U: The longterm effect of an oscillating/rotating electric toothbrush on gingivitis. An 8-month clinical study. J Clin Periodontol 1994;21:139-145.
  7. Ainamo J, Xie Q, Ainamo A, Kallio P: Assessment of the effect of an oscillating/rotating electric toothbrush on oral health. A 12-month longitudinal study. J Clin Periodontol 1997;24:28-33.
  8. Johnson BD, McInnes C: Clinical evaluation of the efficacy and safety of a new sonic toothbrush. J Periodontol 1994; 65:692-697.
  9. Killoy WJ, Love JW, Love J, Fedi PF, Tira DE: The effectiveness of a counter-rotary action powered toothbrush and conventional toothbrush on plaque removal and gingival bleeding. A short term study. J Periodontol 1989; 60(8):473-477.
  10. Cronin M, Dembling W, Warren PR, King DW: A 3 month clinical investigation comparing the safety and efficacy of a novel electric toothbrush (Braun Oral-B 3D Plaque Remover) with a manual toothbrush. Am J Dent 1998;11: S17-S21.
  11. Ho HP, Niederman R: Effectiveness of the sonicare tooth-brush on reduction of plaque, gingivitis, probing pocket depth, and subgingival bacteria in adolescent orthodontic clients. J Clin Dent 1997;8(1):15-19.
  12. Tripeneers LM, Wijgaerts IA, Grognard NA, Dermaut LR, Adriaens PA: Effect of electric toothbrushes versus manual toothbrushes on removal of plaque and periodontal status during orthodontic treatment. Am J Orthod Dentofacial Orthop 1997;111(5):492-497.
  13. Heintze SD, Jost-Brinkman PG, Loundos J: Effectiveness of three different types of electric toothbrushes compared with a manual technique in orthodontic clients. Am J Orthod Dentofacial Orthop 1996;110(6):630-638.
  14. White LW: Efficacy of a sonic toothbrush in reducing plaque and gingivitis in adolescent clients. J Clin Orthod 1996;30(2):85-90.
  15. Truhlar RS, Morris HF, Ochi S: The efficacy of a counter rotation powered toothbrush in the maintenance of endosseous dental implants. J Am Dent Assoc 2000; 131:101.
  16. Wolff L, Kim A, Nunn M, Bakdash B, Hinrichs J: Effectiveness of a sonic toothbrush in the maintenance of dental implants. J Clin Periodontol 1998;25:821-828.
  17. Lang NP, Joss A, Orsani T, Gusberti FA, Siegrist BE: Bleeding on probing. A predictor for the progression of periodontal disease? J Clin Periodontol 1986;13:590-596.
  18. Chaves ES, Wood RC, Jones AA, Newbold DA, Manwell MA, Kornman KS: Relationship of “bleeding on probing” and “gingival index bleeding” as clinical parameters of gingival inflammation. J Clin Periodontol 1993;20:139-143.
  19. Isaacs RL, Beiswanger BB, Rosenfield ST, Crawford JL, Mau, MS, Eckert GJ, Warren PR: A crossover clinical investigation of the safety and efficacy of a new oscillating/ rotating electric toothbrush and high frequency electric toothbrush. Am J Dent 1998;11(1):7-12.
  20. Grossman E, Dembling W, Proskin HM: A comparative clinical investigation of the safety and efficacy of an oscillating/ rotating electric toothbrush and sonic toothbrush. J Clin Dent 1995;6:108-1995.
  21. Heasman PA, Stacey F, Heasman L, Sellers P, Macgregor IDM, Kelly PJ: A comparative study of the Philips HP 735, Braun/Oral B D7 and the Oral B 35 Advantage toothbrushes. J Clin Periodontol 1999;26:85-90.
  22. Barnes CM, Russell CM, Weatherford III, TW: A comparison of the efficacy of 2 powered toothbrushes in affecting plaque accumulation, gingivitis, and gingival bleeding. J Periodontol 1999;70:840-847.
  23. Robinson PJ, Maddalozzo D, Breslin S: A six month clinical comparison of the efficacy of the sonicare and the Braun Oral-B electric toothbrushes on improving periodontal health in adult periodontitis clients. J Clin Dent 1997;7(1) special issue; 4-9.
  24. O’Beirne G, Johnson RH, Persson GR, Spektor MD: Efficacy of a sonic toothbrush on inflammation and probing depth in adult periodontitis. J Periodontol 1996;67:900-908.
  25. Knudsen J, Donnellan J: Reduction of pocket depths in pri-vate practice recall clients using a sonic toothbrush. J Pract Hyg 1998; May/June: 60-64.
  26. Wu-Yuan CD, Anderson RD, McInnes C: Ability of the sonicare electronic toothbrush to generate dynamic fluid activity that removes bacteria. J Clin Dent 1994;5(3):89-93.
  27. McInnes C, Engel D, Moncla BJ, Martin RW: Reduction in adherence of Actinomyces viscosus after exposure to low-frequency acoustic energy. Oral Microbiol Immunol 1992;7:171-176.
  28. Blanco VL, Cobb CM, Williams KB, Manch-Citron JN: In vitro effect of the Sensonic® toothbrush on Treponema denticola. J Clin Periodontol 1997;24:318-323.
  29. MacNeill S, Walters DM, Dey A, Glaros AG, Cobb CM: Sonic and mechanical toothbrushes: An in vitro study showing altered microbial surface structures but lack of effect on viability. J Clin Periodontol 1998;25:988-993.
  30. Van der Weijden GA, Timmerman MF, Reijerse E, Snoek CM, Van der Velden U: Comparison of an oscillating/ rotating electric toothbrush and a ‘sonic’ toothbrush in plaque-removing ability. A professional toothbrushing and supervised brushing study. J Clin Periodontol 1996;23:407-411.
  31. Lang WP, Ronis DL, Farghaly MM: Preventive behaviors as correlates of periodontal health status. J Public Health Dent 1995;55(1):10-17.
  32. Gordon JM, Frascella JA, Reardon RC: A clinical study of the safety and efficacy of a novel electric interdental cleaning device. J Clin Dent 1996;7(3):70-73.
  33. Cronin M, Dembling W: An investigation of the efficacy and safety of a new electric interdental plaque remover for the reduction of interproximal plaque and gingivitis. J Clin Dent 1996;7(3):74-77.
  34. Isaacs RL, Beiswanger BB, Crawford JL, Mau MS, Proskin H, Warren PR: Assessing the efficacy and safety of an electric interdental cleaning device. J Am Dent Assoc 1999;130(1):104-108.
  35. Schmage P, Platzer U, Nergiz I: Comparison between manual and mechanical methods of interproximal hygiene. Quintessence Int 1999;30:535-539.
  36. Pucher J, Jayaprakash P, Aftyka T, Sigman L, Van Swol R: Clinical evaluation of a new flossing device. Quintessence Int 1995;26(4):273-278.
  37. Anderson NA, Barnes CM, Russell CM, Winchester KM: A clinical comparison of the efficacy of an electromechanical flossing device or manual floss in affecting interproximal gingival bleeding and plaque accumulation. J Clin Dent 1995;6:185-187.
  38. Shibly O, Ciancio S, Shostad S, Mather M, Boardman TJ: Clinical evaluation of an automated flossing device versus manual flossing. J Clin Dent 2001;12:63-66.
  39. Spolsky, VW, Perry DA, Meng Z, Kissel P: Evaluating the efficacy of a new flossing aid. J Clin Periodontol 1993; 20(7):490-497. 40. Carter-Hanson C, Gadbury-Amyot C, Killoy W: Comparison of the plaque removal efficacy of a new flossing aid (Quik Floss) to finger flossing. J Clin Periodontol 1996;23(9):873-878.
  40. Chrisou V, Timmerman MF, Van der Velden U, Van der Weijden FA: Comparison of different approaches of interdental oral hygiene: Interdental brushes versus dental floss. J Periodontol 1998;69(7):759-764.
  41. Kleber CJ, Putt MS: Formation of flossing habit using a floss-holding device. J Dent Hyg 1990;64(3):140-143.
  42. Lobene RR: The effect of a pulsed water pressure cleansing device on oral health. J Periodontol 1969;40:51-54
  43. Hoover DR, Robinson HBG: The comparative effectiveness of a pulsating oral irrigator as an adjunct in maintaining oral health. J Periodontol 1971;42:37-39.
  44. Chaves ES, Kornman KS, Manwell MA. Jones AA, Newbold DA, Wood RC: Mechanism of irrigation effects on gingivitis. J Periodontol 1994;65:1016-1021.
  45. Flemmig TF, Newman MG, Doherty FM, Grossman E, Meckel AH, Bakdash, MB: Supragingival irrigation with 0.06% chlorhexidine in naturally occurring gingivitis. I. Six-month clinical observations. J Periodontol 1990;61:112- 117.
  46. Newman MG, Flemmig TF, Nachnani S, Rodrigues A, Calsina G, de Camargo P, Lee Y, Doherty FM, Bakdash MB: Irrigation with 0.06% chlorhexidine in naturally occurring gingivitis II. 6-month microbiological observations. J Periodontol 1990;61:427-433.
  47. Brownstein CN, Briggs SD, Schweitzer KL, Briner WW, Kornman KS: Irrigation with chlorhexidine to resolve naturally occurring gingivitis. A methodologic study. J Clin Periodontol 1990;17:588-593.
  48. Ciancio SG, Mather ML, Zambon JJ, Reynolds HS: Effect of a chemotherapeutic agent delivered by an oral irrigation device on plaque, gingivitis, and subgingival microflora. J Periodontol 1989;60:310-315.
  49. Newman MG, Cattabriga M, Etienne D, Flemmig T, Sanz M, Kornman KS, Doherty F, Moore DJ, Ross C: Effectiveness of adjunctive irrigation in early periodontitis: Multicenter evaluation. J Periodontol 1994;65:224-229.
  50. Flemmig TF, Epp B, Funkenhauser Z, Newman MG, Kornman KS, Haubitz I, Kaiber B: Adjunctive supragingival irrigation with acetylsalicyclic acid in periodontal supportive
    therapy. J Clin Periodontol 1995;22:427-433.
  51. Walsh TF, Glenwright HD, Hull PS: Clinical effects of pulsed oral irrigation with 0.2% chlorhexidine digluconate in clients with adult periodontitis. J Clin Periodontol 1992;19:245-248.
  52. Jolkovsky DL, Waki MY, Newman MG, Otomo-Corgel J, Madison M, Flemmig TF, Nachnani S, Nowzari H: Clinical #02-and microbiological effects of subgingival and gingival marginal irrigation with chlorhexidine gluconate. J Periodontol 1990;61:663-669.
  53. Fine JB, Harper DS, Gordon JM, Hovliaras CA, Charles CH: Short-term microbiological and clinical effects of subgingival irrigation with an antimicrobial mouthrinse. J Periodontol 1994; 65: 30-36.
  54. Felo A, Shibly O, Ciancio SG, Lauciello FR, Ho A: Effects of subgingival chlorhexidine irrigation on periimplant maintenance. Am J Dent 1997;10:107-110.
  55. Watt DL, Rosenfelder C, Sutton CD: The effect of oral irrigation with a magnetic water treatment device on plaque and calculus. J Clin Periodontol 1993; 20:314-317.
  56. Johnson KE, Sanders JJ, Gellin RG, Palesch YY: The effectiveness of a magnetized water oral irrigator (HydroFloss®)on plaque, calculus and gingival health. J Clin Periodontol 1998;25:316-321.
  57. Frascella JA, Fernandez P, Gilbert RD, Cugini M: A randomized, clinical evaluation of the safety and efficacy of a novel oral irrigator. Am J Dent 2000;13:55-58.
  58. Eakle WS, Ford C, Boyd RL: Depth of penetration in periodontal pockets with oral irrigation. J Clin Periodontol 1986;13:39-44.
  59. Braun RE, Ciancio SG: Subgingival delivery by an oral irrigation device. J Periodontol 1992;63:469-472. 61. Cobb CM, Rodgers RL, Killoy WJ: Ultrastructural examination of human periodontal pockets following the use of an oral irrigation device in Vivo. J Periodontol 1988;59: 155-163.
  60. Cutler CW, Stanford TW, Abraham C, Cedarberg RA, Boardman T, Ross C: Clinical benefits of oral irrigation for periodontitis are related to reduction of pro-inflammatory cytokine levels and plaque. J Clin Periodontol 2000;27:134-143.
  61. Kornman KS, Crane A, Wang H-Y, di Giovine FS, Newman MG, Pirk FW, Wilson Jr, TG, Higginbottom FL, Duff GW: The interleukin-1 genotype as a severity factor in adult periodontal disease. J Clin Periodontol 1997;24:72-77.
  62. Tsai C, Ho Y, Chen C: Levels of interleukin-1B and inter-leukin-8 in gingival crevicular fluids in adult periodontitis. J Periodontol 1995;66:852-859.
  63. Offenbacher S, Heasman PA, Collins JG: Modulation of host PGE 2 secretion as a determinant of periodontal disease expression. J Periodontol 1993;64:432-444.
  64. Offenbacher S: Periodontal diseases: Pathogenesis. Ann Periodontol 1996;1:821-878.
  65. Beck J, Garcia R, Heiss G: Periodontal disease and car-diovascular disease. J Periodontol 1996;67:1123-1137.
  66. Offenbacher S, Katz, Fertik G, Collins J, Boyd G, Maynor G, McKaig R, Beck J: Periodontal infection as a possible risk factor for preterm low birth weight. J Periodontol 1996;67:1103-1113.
  67. Understanding and evaluating scientific literature. OSAP Monthly Focus 1999;3:1-8.
  68. Quigley G, Hein J: Comparative cleansing efficiency of manual and power brushing. J Am Dent Assoc 1962, 65:26-29.
  69. Turesky S, Gilmore N, Glickman I: Reduced plaque formation by the chloromethyl analogue of vitamin C. J Periodontol 1970;41:41-43.
  70. Silness J, Löe H: Periodontal disease in pregnancy. II. Correlation between oral hygiene and periodontal condition. Acta Odontol Scand 1964;22:121.
  71. Löe H, Silness J: Periodontal disease in pregnancy: Prevalence and severity. Acta Odont Scand 1963;21:533-551.
  72. Caton J, Polson A: The interdental bleeding index: A simplified procedure for monitoring gingival health. Comp Cont Educ Dent 1985;88:89.
  73. Muhlemann HR, Son S: Gingival sulcus bleeding: A leading symptom in initial gingivitis. Helv Odontol Acta 1971; 15:107-113.
  74. Page RC, et al.: Design and conduct of clinical trials of products designed for the prevention, diagnosis and therapy of periodontitis. Chicago, American Academy of Periodontology, 1995.
  75. Jahn CA: Review of automated plaque removal products. J Pract Hyg 2000;9(5):48-52.